_SA#
PREALIGNER AVAILABILITY
HFP-812, HFP-312
SUMMARY
Report or set wafer orientation
SYNTAX
_SA [Angle]
| Parameters | Necessary Param | Description |
|---|---|---|
| Angle | No | Angle on which wafer to be oriented. |
| Returned Values | Return Error |
|---|---|
| 0 | No Error. |
DEVICE PRECONDITIONS
NONE
EXAMPLE
>_sa
9000
>_sa 18000
>