MVA

MVA#

PREALIGNER AVAILABILITY
HFP-812, HFP-312

SUMMARY
Move Absolute

SYNTAX
MVA [Axis] [Position]

Parameters Necessary Param Description
Axis Yes Axis to move.
Position Yes Absolute position to move to.
Returned Values Return Error
0 No Error.
1
2 Device already running a System or User macro.
3 Interlock.
4 One or more axes servo loop is not enabled.
6 Device not homed.
7 Bad Parameter.
8 No motor power.
10 Axis is outside of limit parameters.

DEVICE PRECONDITIONS
INITIALIZED, SERVO, HOMED

USAGE NOTES
Move an axis to an absolute position.

See also: MVR SON HOM 

EXAMPLE

>RCP
4500, 4000
>MVA T 1000
>0002
>RCP
1000, 4000
>