SOF

SOF#

PREALIGNER AVAILABILITY
HFP-812, HFP-312

SUMMARY
Disables the servo loop.

SYNTAX
SOF [Axis]

Parameters Necessary Param Description
Axis No Specific axis to disable the servo loop to.
Returned Values Return Error
0 No Error.
1
3 Interlock.
7 Bad Parameter.

DEVICE PRECONDITIONS
INITIALIZED

USAGE NOTES
Disables the servo loop to all axes or only to the specific axis requested.

See also: SON POW NOP 

EXAMPLE

>SOF
>