SOF#
PREALIGNER AVAILABILITY
HFP-812, HFP-312
SUMMARY
Disables the servo loop.
SYNTAX
SOF [Axis]
| Parameters | Necessary Param | Description |
|---|---|---|
| Axis | No | Specific axis to disable the servo loop to. |
| Returned Values | Return Error |
|---|---|
| 0 | No Error. |
| 1 | |
| 3 | Interlock. |
| 7 | Bad Parameter. |
DEVICE PRECONDITIONS
INITIALIZED
USAGE NOTES
Disables the servo loop to all axes or only to the specific axis requested.
EXAMPLE
>SOF
>