VEL

VEL#

PREALIGNER AVAILABILITY
HFP-812, HFP-312

SUMMARY
Report or set velocity.

SYNTAX
VEL [Axis] [Value]

Parameters Necessary Param Description
Axis No Axis to report or set.
Value No Value to set to.
Returned Values Return Error
0 No Error.
1
3 Interlock.
5 .
7 Bad Parameter.

DEVICE PRECONDITIONS
INITIALIZED

USAGE NOTES
Report or set an Axis’ current velocity. Issuing a SAVEP after setting to a new value will save over the working speed.

See also: ACC DEC 

EXAMPLE

// HFP-812
>VEL
72000, 8000
>
// HFP-312
>VEL
72000, 8000, 2000
>